Acoustic Room Reverb Time Calculator.
Estimates the reverberation time (RT60) of a room based on its volume, total surface area, and average absorption coefficient, using the Sabine formula.
Suas entradas
Como funciona
- 1
Enter the room volume in cubic meters.
- 2
Enter the total surface area of all room boundaries in square meters.
- 3
Enter the average absorption coefficient (between 0 and 1).
- 4
The calculator applies the Sabine formula to estimate RT60.
0.161 * volume / (surface_area * absorption_coefficient)Perguntas frequentes
What is RT60?
RT60 is the time it takes for a sound to decay by 60 decibels after the source stops. It indicates how reverberant a room is.
What is a good RT60 for a room?
It depends on the use: about 0.4–0.6 s for speech, 1.5–2.0 s for concert halls, and 0.2–0.4 s for recording studios.
How accurate is the Sabine formula?
It works well for rooms with average absorption below 0.3 and fairly diffuse sound fields. For highly absorptive rooms, the Eyring formula is more accurate.
Explorar esta categoria de calculadora
Resultados
Fórmula verificadaReverberation Time (RT60)
0s
Estimativa apenas para orientação geral — verifique decisões importantes com um profissional adequado.
Como funciona
Estimates the reverberation time (RT60) of a room based on its volume, total surface area, and average absorption coefficient, using the Sabine formula.
- Enter the room volume in cubic meters.
- Enter the total surface area of all room boundaries in square meters.
- Enter the average absorption coefficient (between 0 and 1).
- The calculator applies the Sabine formula to estimate RT60.
Fórmulas
A matemática por trás desta calculadora, escrita para que você possa verificar o resultado.
Sabine Formula
V is room volume in m³, A is total surface area in m², α is average absorption coefficient.
Example:
Input: V = 100 m³, A = 150 m², α = 0.2
Calculation: 0.161 × 100 / (150 × 0.2)
Result: ≈ 0.54 s
Casos de uso reais
Onde este cálculo aparece no dia a dia.
Home Theater Setup
Estimate reverb time to decide on acoustic panels for clearer dialogue.
Example: A 50 m³ room with α=0.15 gives RT60 ≈ 1.07 s, which may be too echoey.
Recording Studio Design
Check if a room meets the low RT60 needed for clean recordings.
Example: A 80 m³ studio with α=0.4 gives RT60 ≈ 0.32 s, suitable for tracking.
Classroom Acoustics
Ensure speech intelligibility by keeping RT60 below 0.6 s.
Example: A 200 m³ classroom with α=0.25 gives RT60 ≈ 0.64 s, borderline.
Dicas e erros comuns
Tips
- Measure volume and surface area accurately for better estimates.
- Use average absorption coefficients from material tables.
- For rooms with high absorption (α > 0.3), consider the Eyring formula.
- RT60 varies with frequency; this calculator gives a broadband estimate.
Common Mistakes to Avoid
- Using the floor area instead of total surface area.
- Entering absorption as a percentage (e.g., 20 instead of 0.2).
- Ignoring that the formula assumes a diffuse sound field.